INTAKE AIR TEMPERATURE (IAT) SENSOR NO.2 INSPECTION [MZR-CD (RF Turbo)]
id0140f1806200
Resistance Inspection
1. Remove the IAT sensor No.2. (See INTAKE-AIR SYSTEM REMOVAL/INSTALLATION [MZR-CD (RF Turbo)].)
2. Place the IAT sensor No.2 in water with a thermometer, and heat the water gradually.
3. Measure the resistance between the IAT sensor No.2 terminals using an ohmmeter.
Specification
Water temperature (°C {°F}) |
Resistance (kilohm) |
---|---|
20 {68}
|
2.21—2.69
|
80 {176}
|
0.29—0.35
|
am3zzw00004084
|
Circuit Open/Short Inspection
1. Disconnect the PCM connector. (See PCM REMOVAL/INSTALLATION [MZR-CD (RF Turbo)].)
2. Inspect for open/short circuit in the following wiring harnesses.
am3zzw00004085
|
Open circuit
Short circuit