INTAKE AIR TEMPERATURE (IAT) SENSOR NO.2 INSPECTION [MZ-CD 1.6 (Y6)]
id0140b2806200
Visual Inspection
1. Remove the IAT sensor No.2. (See INTAKE AIR TEMPERATURE (IAT) SENSOR NO.2 REMOVAL/INSTALLATION [MZ-CD 1.6 (Y6)].)
2. Verify that there are no metal shavings on the sensor.
3. Visually inspect the IAT sensor No.2 for the following:
4. Install the IAT sensor No.2. (See INTAKE AIR TEMPERATURE (IAT) SENSOR NO.2 REMOVAL/INSTALLATION [MZ-CD 1.6 (Y6)].)
Resistance Inspection
1. Disconnect the IAT sensor No.2 connector.
2. Measure the resistance between IAT sensor No.2 terminals A and B.
am3zzw00001578
|
IAT sensor No.2 resistance (reference)
Intake air temperature (°C {°F}) |
Resistance (kilohm) |
---|---|
10 {50.0}
|
Approx. 22.42
|
26 {78.8}
|
Approx. 10.72
|
Circuit Open/Short Inspection
1. Disconnect the PCM connector. (See PCM REMOVAL/INSTALLATION [MZ-CD 1.6 (Y6)].)
2. Inspect the following wiring harness for open or short circuit (continuity check).
am3zzw00001579
|
Open circuit
Short circuit