NEUTRAL SWITCH INSPECTION [MZR-CD (RF Turbo)]


id0140f1800800

Note
•  Perform the following test only when directed.

Continuity Inspection

1.  Disconnect the negative battery cable.

2.  Remove the neutral switch. (See NEUTRAL SWITCH REMOVAL/INSTALLATION [A26M-R].)

3.  Inspect for continuity between the neutral switch terminals using an ohmmeter.

•  If the neutral switch is okay, perform the “Circuit Open/Short Inspection”
•  If not as specified, replace the neutral switch. (See NEUTRAL SWITCH REMOVAL/INSTALLATION [A26M-R].)

Specification

am3zzw00004064
am3zzw00004065


Circuit Open/Short Inspection

1.  Disconnect the PCM connector. (See PCM REMOVAL/INSTALLATION [MZR-CD (RF Turbo)].)

2.  Inspect for open/short circuit in the following wiring harnesses.

•  If there is open/short circuit, repair or replace wiring harnesses.

am3zzw00004066

Open circuit

•  Neutral switch terminal A and PCM terminal 110
•  Neutral switch terminal B and body ground


Short circuit

•  Neutral switch terminal A and body ground
•  Neutral switch terminal A and power supply
•  Neutral switch terminal B and power supply