VARIABLE BOOST CONTROL (VBC) CHECK VALVE INSPECTION [MZR-CD (RF Turbo)]
id0113f1777700
1. Remove the VBC check valve. (See INTAKE-AIR SYSTEM REMOVAL/INSTALLATION [MZR-CD (RF Turbo)].)
2. Blow through port A and verify that the airflows from port B.
am3zzw00004264
|
3. Blow through port B and verify that the air does not flow from port A.