SELECTOR CABLE ADJUSTMENT


id051800800700

1.  Remove the console. (See CONSOLE REMOVAL/INSTALLATION.)

2.  Shift the selector lever to the P position.

3.  Unlock the lock piece of the selector cable (selector lever side) in the order as shown in the figure.

am3zzw00002403
am3zzw00002404

4.  Verify that the manual shaft is in the P position.

5.  Lock the lock piece and safety lock of the selector cable (selector lever side) in the order as shown in the figure.

am3zzw00002405
am3zzw00002406

6.  Install the console. (See CONSOLE REMOVAL/INSTALLATION.)

7.  Shift the selector lever from the P position to M range, and make sure that there are no other components in that area to interfere with the lever.